    SN: 8367
    Rebuild  Complete
    * Rebuild Started
    * Unit stripped to chassis in preparation for a thorough  cleaning
    * Unit cleaned, scrubbed, mega-gunk and nicotine removed. Water wash and let air dry for 24 hours before mechanical work begins.
    * Mechanical work underway: Tube sockets, terminal strips, rear panel rework ( install MS 8-32 nutplates (20)
    * Power transformer output wiring replaced
    * Power Transformer end bells repainted
    * Power Transformer re-installed.
    * LV, Bias & modulator tube socket wiring complete
    * Power Transformer wiring complete
    * New Power & PTT/Manual switches installed
    * Mil grade ceramic modulator tube sockets installed
    * Mil grade ceramic PA tube sockets (3) installed
    * Jumper socket installed
    * Jumper socket heater wiring installed
    * PA & Modulator bias wiring reworked and installed
    * Fuse Holder for HV transformer installed on rear panel
    * New ceramic meter switch installed and wired.
    * Microphone and Key Jack installed
    * HV rectifier heater wiring installed
    * HV rectifier tubes new ceramic mil grade sockets installed
    * Under-chassis wiring rebuild approximately 60% complete. RF string rebuild complete
    * Tube heater circuit test, all tubes in place
    * AC primary circuits wiring completed
    * Separate AC Line fuse added for HV transformer
    * PTT relay circuit tested
    * PA Screen & Grid wiring installed
    * Re-mounted R-12
    * Microphone input transformer installed
    * Fabricated and installed sub-chassis for: +300V regulator, Solid State Drive circuits,Adjustable bias circuits
    * Installed and aligned band switch cam and cam striker assembly
    * Installed VFO Module
    * Bias circuits ( PA & Modulator) circuits tested
    * Power supply test points installed: +300VDC regulated, PA & Modulator Bias
    * +300VDC regulator circuit tested
    * Solid State Drive Control circuit tested
    * NOTE: Microphone Audio Clipper Circuit has been removed (bypassed, all components except tube socket have been removed). Panel control left in place but non-functional.
    * VFO output switching circuits test
    * Microphone input, PTT and Keying circuits connected to their appropriate rear panel connectors.
    * Keying circuit testing
    * Modulator tubes anode cap assemblies installed
    * PA Tubes Bias level checked at PA tube grids.
    * Modulator tubes bias level checked at Modulator tube grids.
    * Installed temporary panel meter
    * Oscillator, Buffer, Grid metering tested all bands (VFO Input, CW Mode)
    * Installed VFO shroud
    * Enlarged VFO coupler access chassis opening
    * Re-check +300VDC regulator under load conditions.
    * Install Plate Choke and HV bypass capacitors
    * Re-check bias circuits under load conditions
    * Adjusted Keyer circuit: tested CW & AM keyer operation.
    * Microphone preamplifier circuit tested to grids of modulator tubes.
    * Soldered RF Connections around PA Tank coil: Note: In addition to secure mechanical  connections, we solder all RF connections. The only non-soldered RF circuit connections are the PA Tube anode cap connector assemblies.
    * Install top-of-chassis shield assembly
    * Fabricate, install and test neon "transmit" lamp assembly.
    * Installed SSB input connectors and cables.
    * Fabricated (3) clamp-on PA Anode connectors
    * Installed partial PA plate connections ( silver plated brass)
    * Installed Sprague 30KV plate blocking capacitor
    * Install 40 meter PA tuning shunt capacitors ( 150pf total). We use HV doorknob capacitors.
    * Installed HV Power transformer
    * Installed HV Filter Choke
    * Installed HV Filter Capacitor/Bleeder assembly
    * Tested HV circuit ( No load). Test satisfactory. Bleeder circuit test satisfactory
    * Installed front panel
    * Cleaned & repainted meter rear cover, replaced panel meter filter components
    * Panel meter re-connected
    * Control knobs cleaned, new allen set screws installed, knobs installed
    * Sub-panel edge gasket replaced
    * New "Transmit" indicator lamp holder installed ( Red Cap)
    * Tested Panel meter
    * Installed ball drive snubber assembly
    * Installed front sub-panel
    * Replaced front sub-panel edge gasket
    * Installed VFO dial and VFO tuning knob
    * Installed Buffer and PA tuning knobs
    * Fabricated and installed new (3) PA Suppressor assemblies
    * Installed all loading fixed capacitors
    * Adjusted PA Clamp circuit per manual
    * Adjusted Modulator Idle IP per manual.
    * Installed new 30KV 500pf plate blocking capacitor
    * Installed new PA Tuning Shunt Capacitors
    * Final testing complete
    * Modulation envelope test complete
    * Cabinet included.
    * This is the last remaining Valiant that we have rebuilt.
    * Want to reserve this unit ? follow the links below for more information.
    * All Sales Final, No Warranties expressed or implied. No returns. Technical assistance if necessary via Email.
    * This transmitter does NOT have a functioning 11 meters, so don't ask.
    * Local Pickup Only.( We do not fabricate shipping containers)..  Feel Free to make your own shipping arrangements.
    Tubes removed and packaged separately. Gross weight ) approximately 100#.